Event 38213, «Battery charge low», is the low battery warning for the measurement board (SMB) of an ABB robot. ABB's Product Manuals describe it as follows: the warning appears when the battery needs changing.
What 38213 means
The measurement board battery sits in the manipulator, not the cabinet, and keeps the axes' revolution counters alive while the robot is without power. The 38213 is the advance warning: it says that battery is now due for changing.
What ABB asks for in its manuals is that, to avoid an unsynchronised robot, the controller be kept powered up until the battery is changed.
When it triggers depending on the measurement board
The timing of the warning depends on the robot's measurement board variant:
- Board with 3-pole battery contact: the typical lifespan of a new battery is 36 months.
- Board with 2-pole battery contact: the warning triggers when the remaining backup capacity, with the robot powered off, falls below 2 months. The typical lifespan of a new battery is 36 months if the robot is switched off 2 days a week, or 18 months if it is switched off 16 hours a day.
For long shutdowns, ABB describes a battery shutdown service routine that extends its life; it's in the controller's operating manual (IRC5 with FlexPendant or OmniCore).
What to do when it appears
- Do not power down the controller until the battery is changed: this is ABB's recommendation to avoid losing synchronisation.
- Check which board variant that robot has (2-pole or 3-pole contact). The manual warns that each variant uses its own battery and that the battery contact must not be changed.
- Change the battery following the model's Product Manual, under the task «Replacing the SMB battery». If the robot has already lost its counters, that's a different warning: we explain it in revolution counter not updated on ABB.
- Note down the date of the change for the next cycle.
Our criterion, which is a PAS guideline and not the manufacturer's, is to change the battery every 24 months on the ABB robots we maintain, without waiting for the warning. More on what this battery is for in SMB batteries on ABB robots.
Frequently asked questions
Is 38213 a fault?
It is not a fault with the arm: it is a maintenance warning. According to the manuals, it indicates that the battery needs changing.
How much time is there between the warning and the problem?
It depends on the board. On the 2-pole version, the manual sets the warning at less than 2 months of remaining backup with the robot powered off. On the 3-pole version, the manual does not give a timeframe from the warning. In both cases, ABB recommends not powering down the controller until the change is made.
Which robots does it appear on?
The event text appears in ABB's Product Manuals for, among others, the IRB 4400, IRB 6640 and IRB 6700. Each model has its own manual.
Sources
- Product manual IRB 4400, 3HAC022032-001 Rev. AA, pp. 96 and 107.
- Product manual IRB 6640FP, 3HAC040586, pp. 120 and 187.
- Product manual IRB 6700, 3HAC044266-001 Rev. AH, p. 195.