This manual does not use message numbers for these warnings: it indicates the status via the LEDs on the CCU_SR unit. This applies to the KR C4 compact; for other KR C4 cabinets, check the relevant manual.
What these LEDs indicate
In the KR C4 compact manual, these green LEDs on the CCU_SR indicate the voltage from the main power supply:
- 27V LED (unbuffered voltage from the main power supply): off means there is no supply voltage. The manual states to check the supply at X1 (nominal voltage 27.1 V).
- PS1 LED (Power Supply 1, short buffering): off means there is no voltage. The manual states to check the supply at X1 (27.1 V) and whether the drive bus is disconnected (BusPowerOff state).
- PS2 LED (Power Supply 2, medium buffering): off means there is no voltage. The manual states to check the supply at X1 and whether the control unit is in Sleep state.
- PS3 LED (Power Supply 3, long buffering): lit indicates there is supply voltage.
How to read it on the shop floor
- All three LEDs point to the same starting point: the supply at X1.
- The manual differentiates by state: BusPowerOff for PS1 and Sleep for PS2.
- Our approach, which is a PAS guideline and not the manufacturer's: interventions inside the cabinet are carried out by qualified personnel, with the relevant variant's manual to hand.
Frequently asked questions
What voltage should be present at X1?
The manual gives a nominal voltage of 27.1 V.
What does the Sleep state mean?
The manual mentions it as a possible cause of PS2 being off, without describing it in this table.
Sources
- KR C4 compact Operating and Programming Instructions, BA KR C4 compact V14 (edition 11.09.2020), chap. 11.1, pp. 186 and 187.