This manual does not use message numbers for these alerts: it indicates the status through the LEDs on the CCU_SR unit. This applies to the KR C4 compact; for other KR C4 cabinets you need to check the relevant manual.

What these LEDs indicate

The PWR/3,3V, PWR/2,5V and PWR/1,2V LEDs on the CCU_SR are green and indicate the voltage supplied to the CIB_SR. According to the KR C4 compact manual:

  • On: supply voltage is present.
  • Off: no supply voltage present. The manual gives the same four checks for all three LEDs:
    • check fuse F17-3;
    • check that jumper connector X308 is fitted;
    • check fuse F308;
    • if the supply is external, via X308, check the external supply (rated voltage 24 V).

How to read this on the shop floor

  • All three LEDs share the same checklist: start with the fuses and the X308 jumper.
  • Our approach, which is a PAS guideline rather than the manufacturer's: work inside the cabinet should be carried out by qualified personnel, with the variant's manual to hand.

Frequently asked questions

What does each LED power?

The manual describes them as the voltage for the CIB_SR, without further detail.

Does this apply to other KR C4 cabinets?

We haven't verified this: this information comes from the KR C4 compact manual.

Sources

  • KR C4 compact operating instructions manual, BA KR C4 compact V14 (edition 11.09.2020), chap. 11.1, p. 184.

We check your KUKA fleet

We diagnose the cabinet using the manual for its variant and provide documented records of the status of each controller. Fleet diagnostics are free of charge.