This manual does not use message numbers for these warnings: it indicates the status via the LEDs on the CCU_SR unit. This applies to the KR C4 compact; for other KR C4 cabinets, you need to check the relevant manual.
What RUN SION and RUN CIB_SR indicate
RUN SION is the status of the EtherCAT safety nodes, and RUN CIB_SR is the status of the ATµC EtherCAT I/O nodes. Both LEDs are green and use the same states:
- On: operational (normal state).
- Off: Init (after connection).
- Flashing at 2.5 Hz: Pre-Op (intermediate state at start-up).
- Single flash: Safe-OP.
- Flashing at 10 Hz: initialisation or start-up, for firmware updating.
How to read it on the shop floor
- These are status indicators: in every case, the manual does not call for any action in the solution column.
- The Init and Pre-Op states are normal during start-up: what matters is whether the LED reaches a steady on (operational) state.
- Our own guideline, which is a PAS criterion and not the manufacturer's: work inside the cabinet should be carried out by qualified personnel, with the manual for the specific variant to hand.
Frequently asked questions
What is Safe-OP?
The manual lists it as one of the LED states (single flash), with no further explanation in this table.
Does this apply to other KR C4 cabinets?
We haven't verified this: this information comes from the KR C4 compact manual.
Sources
- KR C4 compact Operating Instructions, BA KR C4 compact V14 (edition 11.09.2020), chap. 11.1, pp. 183 (RUN SION) and 186 (RUN CIB_SR).