Events 10011, «Motors ON state», and 10012, «Safety guard stop state», are normal states of an ABB controller: the first appears when the motors are connected via the enabling device and the second when it is released. The cabinet manuals use them as the correct outcome of the functional tests.
What the manuals say
In the Product Manuals for the IRC5 and the OmniCore E10, the motor contactor test is carried out in manual mode:
- Press the three-position enabling device to the middle position and hold it there. The test is passed if 10011 «Motors ON state» appears in the event log. If 37001 «Motor on activation error» appears, the test fails and the cause must be found.
- Release the enabling device. The test is passed if 10012 «Safety guard stop state» appears. If 90227 «Motor contactor conflict» appears, the test fails and the cause must be found.
How to read this on the shop floor
- 10011 when the motors are connected and 10012 when the enabling device is released are the expected messages.
- 37001 and 90227 are, according to the manual, the messages that make the test fail. The manual does not give a list of causes: it simply states that the cause of the failure must be found.
- Our approach, which is a PAS guideline and not the manufacturer's: when a 37001 or a 90227 appears during a test, it is resolved before the robot is signed off for production.
Frequently asked questions
Is 10012 a fault?
No. In these tests it is the message that is expected to appear when the enabling device is released.
Is it the same on the IRC5 and the OmniCore?
The IRC5 and OmniCore E10 manuals use the same four messages (10011, 10012, 37001 and 90227) in this test. For other cabinets, check their own manual.
Sources
- Product manual IRC5, 3HAC047136-001 Rev. AH, p. 217 (test of motor contactors K42 and K43).
- Product manual OmniCore E10, 3HAC079399-001 Rev. S, p. 127 (test of safety switches, motors).