Llamar Email Contacto LinkedIn

Contacto

+34 670 42 91 54
info@pasrobotics.com

ABB 10013 Emergency stop state: not a fault

Event 10013, «Emergency stop state», is the message the ABB controller logs when an emergency stop is pressed. It does not indicate a fault: in ABB's cabinet manuals, it is the correct outcome of the emergency stop functional test.

What the manuals say

The cabinet Product Manuals describe the test on the operator panel's mushroom button and on the FlexPendant's: start the system, press the emergency stop, and check the event log.

  • IRC5 Single Cabinet: the test passes if 10013 «Emergency stop state» appears. It fails if 10013 does not appear, or if 90223 «Emergency stop conflict» appears. After the test, release the mushroom button and press the motors button to exit the emergency stop state.
  • OmniCore E10: the test passes with 10013 in the log. It fails if it does not appear, or if 20223 «Emergency stop conflict» or 90780 «Two-channel fault in Safety Controller» appears. On robots set up for collaborative applications, the manual states that 90518 «Safety controller Emergency stop triggered» appears by default, alongside 10013.

Note that the conflict message changes between the two cabinets: 90223 on the IRC5 Single Cabinet and 20223 on the OmniCore E10.

How to read it on the shop floor

  • Seeing 10013 straight after pressing the mushroom button is the expected result.
  • If you press the mushroom button and 10013 does not appear, or a conflict message appears, the manual deems the test failed and calls for finding the cause.
  • Our criterion, which is a PAS guideline and not the manufacturer's: a robot with a failed emergency stop test does not return to production until the cause is resolved.

Frequently asked questions

Is 10013 a fault?

No. It is the logged emergency stop state: it appears when the mushroom button is pressed.

What is the difference between 90223 and 20223?

They are the emergency stop conflict message on two different cabinets: 90223 appears in the IRC5 Single Cabinet manual and 20223 in the OmniCore E10 manual. For other cabinets, check their own manual.

Which cabinets have we checked this on?

On the Product Manuals for the IRC5 (Single Cabinet) and the OmniCore E10. Each cabinet comes with its own manual.

Sources

  • Product manual IRC5, 3HAC047136-001 Rev. AH, p. 214 (emergency stop test function).
  • Product manual OmniCore E10, 3HAC079399-001 Rev. S, p. 124.

We service your ABB fleet

We check the safety functions and measurement battery of each robot during the service, using its cabinet's manual. Fleet diagnostics are free of charge.

Request a free diagnostic